Installation Instructions for
Water Methanol Stage 2
Installation- Mechanical
Step 1 Reservoir Install
Install 1/8” NPT – ¼” OD elbow into 3/8-1/8 NPT reducer bushing using GOOP sealant (Right). Install this
assembled tting with GOOP sealant into the bottom of the reservoir. Note location options for the included low
level warning light sensor. The nozzle, not the reservoir, should be the highest point in the system.
Optional: The factory windshield washer reservoir can be used as the reservoir for your system, using optional
part number 15050.
Drill 9/16” hole in desired bulkhead location.
Remove one nut from bulkhead and turn the remaining nut until it is at the very end.
Feed red tubing through the drilled hole and up and out of the top of the reservoir.
Attach tubing to the bulkhead on the side opposite the nut.
Pull the tubing through the bulkhead hole until the bulkhead seats against the inside of the reservoir.
Apply GOOP sealant (included) around bulkhead.
Slide the nut you had previously removed up onto the tube and thread onto bulkhead.
• While pulling rmly on the red tubing, tighten the outer nut using a 17mm socket (only needs to be hand
tight). A ratchet is not needed.
Once sealant has set, ll reservoir with water and check for leaks.
Step 2 Pump Install
Mount the pump so the inlet is positioned at the lowest point of the reservoir or lower.
Pump can be mounted horizontally or vertically using the supplied screws and washers.
Ensure that no sharp bends in the high pressure tube occur near the pump. Sharp bends
can cause stress on the inlet and outlet ports of the pump, causing leaks. Trim tube with
a utility knife or razor blade, making sure to eliminate any burrs or kinks on the end.
Insert rmly into the pump about ½ inch through the light grey locking collar. Note the
arrows indicating ow direction on the top of the pump. To remove the hose, gently and
evenly push the light grey locking collar into the head unit of the pump, then pull on the
hose gently.
Measure the distance from the reservoir outlet to the pump inlet. Cut the ¼” red tubing
using utility knife. Make cuts are as square as possible.
Ensure there are no kinks in the tubing and insert tubing into quick disconnects at pump
and reservoir until fully seated. Keep the pump within 2 feet of the reservoir.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Installation Instructions for

Installation Instructions for Water Methanol Stage 2Installation- MechanicalStep 1 Reservoir Install Install 1/8” NPT – ¼” OD elbow into

Page 2 - Incorrect

Step 3 Nozzle SelectionNozzle sizing is a function of horsepower, which approximates the engine airfl ow, and boost, which approximates intake charge h

Page 3

The nozzle is mounted using its external 1/8 NPT threads. Tighten the nozzle and nozzle holder assembly one half turn past fi nger tight using GOOP to

Page 4

Installation - ElectricalVariable Controller InstallationAttach the controller to secure location with easy access in engine bay or passenger compartm

Page 5 - Pump Output %

NO3 Prong To 12V Key-On Power Pump Low Fluid LED Injection Status LED Air Flow Throttle Plate +12 Volt Key On Engine Ground Wire

Page 6

Nozzle Identifi cation Chart:Nozzle Number Nozzle Size Nozzle Number Nozzle Size1 60 ml/min 4 225 ml/min2 100 ml/min 5 375 ml/min3 17

Page 7

Tuning Quick ReferenceThe power potential of the system is realized through increased boost and/or timing. The large gains on octane and cooling provi

Page 8 - Low Fluid LED

• Connect one black wire from level switch to ground.• Connect other black wire from level switch to white wire from LED. • Connect red wire from